Phone us +86 13760978054
WE ARE AT East of Block 9, Kidford Industrial Park, South Huabao Road, Chancheng District,Foshan City.GuangDong Province,China.
Email Us sales1@neexgent.com

On off grid10kw hybrid solar inverter 48v mpp inverter solar power system

• Pure sine wave output
• Self-consumption and deed in to the grid
• Programmable supply priority for PV, Battery or Grid
• User-adjustable battery charging current suits different types of batteries
• Programmable multiple operation modes: Grid-tie,Off-grid and grid-tie with backup
• Built-in timer for various mode of on/off operation
• Multiple communication for USB.RS232,Modbus and SNMP
• Monitoring software for rel-time status display and control
• Parallel operation up to 6 units for 10KW

• Pure sine wave output
• Self-consumption and deed in to the grid
• Programmable supply priority for PV, Battery or Grid
• User-adjustable battery charging current suits different types of batteries
• Programmable multiple operation modes: Grid-tie,Off-grid and grid-tie with backup
• Built-in timer for various mode of on/off operation
• Multiple communication for USB.RS232,Modbus and SNMP
• Monitoring software for rel-time status display and control
• Parallel operation up to 6 units for 10KW

 

best solar inverter10kva solar invertersolar hybrid grid tie inverterdigital solar inverter

 

Tags:

            

Technical Specifications:

Model

HYG1033

PHASE

3-phase in/3-phase out

Max. PV INPUT POWER

14850W

Rated Output Power

10000W

Maximum Charging Power

9600W

GRID TIE OPERATION

PV INPUT (DC)

Nominal DC Voltage/Max. DC Voltage

720 VDC/900 VDC

Start-up Voltage/lnitial Feeding Voltage

320 VDC/350 VDC

MPP Voltage Range

400 VDC-800 VDC

Number of MPP Trackers

2/2x18.6A

Maximum Input Current

2/2x18.6A

GRID OUTPUT (AC)

Nominal Output Voltage

230 VAC (P-N)/400 VAC (P-P)

Output Voltage Range

184-265 VAC* per phase

Nominal Output Current

14.5A per phase

Power Factor

> 0.99

EFFICIENCY

Maximum Conversion Efficiency (DC/AC)

96%

European Efficiency@Vnominal 

95%

OFF GRID OPERATION

AC INPUT

AC start-up Voltage

120-140 VAC per phase/180 VAC per phase

Auto Restart Voltage 

170-280 VAC per phase

Acceptable Input Voltage Range 

170-280 VAC

Max. AC Input Current 

40A

PV INPUT (DC)

Max. DC Voltage

900 VDC

MPP Voltage Range

400 VDC-800 VDC

Number of MPPTrackers/Max. Input Current 

2/2x18.6A

BATTERY Mode Output (AC)

Nominal Output Voltage

230 VAC (P-N)/400 VAC (P-P)

Output Waveform

Pure Sine Wave

Efficiency (DC to AC)

91%

HYBRID OPER/EON

PV INPUT (DC)

Nominal DC Voltage/Max. DC Voltage

720 VDC/ 900 VDC

Start-up Voltage/lnitial Feeding Voltage

320 VDC/ 350 VDC

MPP Voltage Range

400 VDC-800 VDC

Number of MPP Trackers/Max. Input Current

2/2x18.6A

GRID OUTOUT (AC)

Nominal Output Voltage

230 VAC (P-N)Z

400 VAC (P-P)

Output Voltage Range

184-264.5 VAC* per phase

Nominal Output Current

14.5A per phase

AC INPUT

AC Start-up Voltage/Auto Restart Voltage

120-140 VAC per phase/180 VAC per phase

Acceptable Input Voltage Range

170-280 VAC per phase

Max. AC Input Current

40A

BATTERY MODE OUTPUT (AC)

Nominal Output Voltage

230 VAC (P-N)/400 VAC(P-P)

Efficiency (DC to AC)

91%

BATTERY& CHARGER

Battery DC Voltage

48V

Max. Charging Current 

Default 60A, 10A-200A (Adjustable)

GENERAL

PHYSICAL

Dimension, DxWxH (mm)

167.5x500x622

Net weight (kgs)

45 

INTERFACE

Communication Port

RS-232/USB and CAN Interface

ENVIRONMENT

Humidity

0 -90%RH

Operating Temperature 

-10 to 55 ℃

Altitude

0-1000 m**