This product is a new type of backup power supply for the development of high-tech products, with integration, miniaturization, light, intelligent, standardized, environmental protection and other characteristics, can be widely used in indoor distribution stations, integrated base stations, marginal stations, ETC, distributed power supply and other fields.

   rack mount 48v ups48v rack mount batteryrack for ups batterylifepo4 battery rackrack mount solar battery48v 50ah rack batteryess battery racksolar battery storage rack

Tags:

            

Adopted by the high safety performance, lithium battery cathode material for lithium iron phosphate, high safety, high stability, high cycle life, high specific energy, specific power, low temperature performance is superior, but large current charge and discharge, and many other advantages, at the same time, using suitable for communication demand special high performance battery management system (BMS), with the charge, over discharge, short circuit, over-current (load), temperature, flow, total pressure protection, charging under the secondary electricity, balanced and various protective functions, and provides the bluetooth 、CAN 、RS485 communication interface and the upper machine to realize remote monitoring, can be connected to the base station power environmental monitoring systems,Intelligent software anti-theft design,Ensure the life of lithium battery and reduce the daily maintenance work.
Standard design, suitable for installation in 19-inch standard cabinet, low operating environment requirements (can be in -20 ~ 60℃, humidity < 95% normal work), small size, light weight, easy installation, simple maintenance in the later stage, can save considerable upfront investment and maintenance costs in the later stage.

BMS/PCM parameters

 

No.

Project

 Details

Guideline

(The set value is subject to the actual set value)

1

overcharge protection

Single cell overcharge alarm voltage

3.6±0.02V

overall overcharge alarm voltage

57.6±0.5V

single cell overcharge detection  voltage

3.65±0.02V

overall overcharge alarm voltage

58.4±0.5V

2

over-discharge protection

Single cell over discharge alarm voltage

2.8±0.02V

overall over discharge alarm voltage

44.8±0.5V

over discharge detection voltage

2.5±0.02V

overall discharge detection voltage

40.0±0.5V

3

over current protection

charge over current  alarm current

105.0A±0.5A

Discharge over current alarm current 1

105.0A±0.5A

Discharge over current protection current 1

110.0A±0.5A

Discharge over current detection delay time 1

1S

Discharge over current protection current 2

150.0A±0.5A

Discharge over current detection delay time 2

500.0ms

Charging over current protection current

110.0A

Charge over current detection delay time

1S

Charge over current protection release conditions

Delayed recovery

4

                   short circuit protection

 Protection conditions

 External circuit short circuit

 Detection delay time

≤1mS

 Protection release conditions

Load disconnect

If the short circuit is triggered multiple times, the lock is in the protection state. After the user needs to check the external circuit, reset resets the BMS to release the protection

5

      temperature protection

Charging high temperature protection conditions

65

Charging low temperature protection conditions

-5

Discharging high temperature protection conditions

65

Discharging low temperature protection conditions

-20

6

charge balance

Balanced opening voltage

3.45V±0.02V

Balanced opening pressure difference

50mV

Balance current

85mA±20mA

7

 continuous current

Maximum continuous charge and discharge current

100.0A

8

 charging current limit

Need to be turned on for parallel use

20A±1A

9

communication

RS232/RS485

The default baud rate is 9600bit/S

 10

 power consumption

Current consumption during circuit operation

≤45mA

Sleep mode current consumption

≤100μA

L1(mm)

L2(mm)

W(mm)

H(mm)

438

482

530

222

Product packaging requirements

The sketch, sizes, color of marking should match GB/T191-2000 requests.
1.Model and specification of product;
2.Quantity;
3.Measure up marking;
4.Manufacturing date  
5.Other markings (color.etc).
6.scratch, flaw, crack, and leakage are not allowed.

Package:

Sealing box, packing belt, batch matching stack board guard angle, layer height in line with the outer carton load-bearing requirements.

Applications of UPS systems include medical facilities, life support systems, data storage and computer systems, emergency equipment, telecommunications, industrial processing and online management systems. Static switches provide power redundancy in the event of UPS failure or overload.uninterrupted power source