• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
• Built-in MPPT solar charge controller 80A/100A/200A
• MPPT efficiency max 98%
• Powerful charge rate up to 140Amp
• DC start &Automatic Self-Diagnostic Function
• WIFI / USB monitoring function (wi-fi optional)
• Supporting AGS, BTS port
• Compatible to generator
NG3500 PRO series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger
to offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery
charging current, AC/solar charger priority, and selectable input voltage based on different applications.
Tags:
MODEL |
NG35 PRO4K |
NG35 PRO5K |
NG35 PRO6K |
NG35 PRO8K |
NG35 PRO10K |
NG35 PRO12K |
|||
Nominal Battery System Voltage |
24V |
48V |
24V |
48V |
48V |
48VDC |
48VDC |
48VDC |
|
INVERTER |
Rated power |
4KW |
5KW |
6KW |
8.0KW |
10.0KW |
12.0KW |
||
Surge rating |
12000VA |
15000VA |
18000VA |
24000VA |
30000VA |
36000VA |
|||
Capable of starting electric motor |
2HP |
2HP |
3HP |
4HP |
5HP |
6HP |
|||
Waveform |
Pure sine wave \ same as input (bypass mode) |
||||||||
Nominal output voltage RMS |
220V \ 230V \ 240VAC (±10%RMS) |
||||||||
Output frequency |
50Hz \ 60Hz+0.3Hz |
||||||||
Inverter effciency(peak) |
>85% |
>88% |
|||||||
Line mode efficiency |
>95% |
||||||||
Power factor |
1.0 |
||||||||
Typical transfer time |
20ms(max) |
||||||||
AC INPUT |
Voltage |
230VAC |
|||||||
Selectable voltage range |
90-280 VAC (APL) |
||||||||
Frequency range |
50Hz \ 60Hz |
||||||||
BATTERY |
Low battery voltage cutoff |
20-24VDC for 24VDC mode (40-48VDC for 48VDC mode) |
|||||||
Low battery voltage recover |
21-25VDC for 24VDC mode (42-50VDC for 48VDC mode) |
||||||||
High battery voltage cutoff |
30VDC for 24VDC mode (60VDC for 48VDC mode) |
||||||||
High battery voltage recover |
28.5VDC for 24VDC mode (57VDC for 48VDC mode) |
||||||||
Idle consumption-search mode |
<30W when power saver on |
<80W when power saver on | |||||||
AC CHARGER |
Output voltage |
Depends on battery type |
|||||||
Charger AC input breaker rating |
40A |
40A |
50A |
80A |
80A |
80A |
|||
Overcharge protection S.D. |
31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) |
||||||||
Maximum charge current |
80A |
60A |
100A |
70A |
80A |
100A |
120A |
140A |
|
BTS |
Continuous output power |
Yes Variances in charging voltage & S.D. voltage base on the battery temperature |
|||||||
BYPASS |
Input voltage waveform |
Sine wave (grid or generator) |
|||||||
Nominal input frequency |
50Hz or 60Hz |
||||||||
Overload protection (SMPS Load) |
Circuit breaker |
||||||||
Output short circuit protection |
Circuit breaker |
||||||||
Bypass breaker rating |
40A |
63A |
63A |
63A |
|||||
Max bypass current |
40Amp |
80Amp |
|||||||
SOLAR |
Maximum PV charge current |
80A |
100A(200A optional) |
||||||
DC voltage |
24V \ 48V Auto work |
48V |
|||||||
Maximim PV array power |
2000W |
4000W |
2000W |
4000W |
4000W |
5000W(10000W for 200A optional) |
|||
MPPT range @ operating voltage(VDC) |
32-145VDC for 24V mode,64-145V for 48V mode |
64~145VDC |
|||||||
Maximum PV array open circuit voltage |
145VDC |
||||||||
Maximum effciency |
>98% |
||||||||
Standby power consumption |
<2W |
||||||||
MECHANICAL |
Mounting |
Wall mount |
|||||||
Dimensions (W*H*D) |
620*385*215mm |
670*410*215mm |
|||||||
Net weight (solar CHG) (kg) |
36 |
41 |
41 |
69+2.5 |
75.75+2.5 |
75.75+2.5 |
|||
Shipping dimensions (W*H*D) |
755*515*455mm |
884*618*443mm |
|||||||
Shipping weight (Solar CHG) (kg) |
56 |
61 |
64 |
82.5+2.5 |
89+2.5 |
92+2.5 |
|||
OTHER |
Operation temperature range |
0°C to 40°C |
|||||||
Storage temperature |
-15°C to 60°C | ||||||||
Audible noise |
60dB MAX | ||||||||
Display
|
LED+LCD
|
||||||||
Loading (20GP/40GP/40HQ) |
140pcs \ 280pcs \ 320pcs |