Type |
Hybrid solar inverter |
Max.Power |
10KW |
Output Voltage |
EU And US Standard |
Certificate |
PSE, FCC, CE, UN38.3, Msds, UL, SAA And ROHS |
Lead Time |
10 Days |
Payment |
T/T, L/C,Western Union |
Warranty |
25 Years |
Equipped with an MPPT solar charge controller, this system is designed to efficiently harness and regulate DC power
from the solar array for battery bank charging. Its transformer-less architecture ensures robust power conversion within
a compact footprint, delivering high efficiency. Encased in a durable aluminum housing and featuring an integrated
interface system, it strikes a balance between ruggedness and user-friendly operation.
Thanks to its lightweight and portable nature, installation is a breeze. This inverter stands out as the ideal choice for
modest PV installations, whether for small-scale solar plants or for individual use in both indoor and outdoor settings
within residences.
Product Features:
Tags:
Technical Specifications:
Model |
NGX1033 |
PHASE |
3-phase in/3-phase out |
Max. PV INPUT POWER |
14850W |
Rated Output Power |
10000W |
Maximum Charging Power |
9600W |
GRID TIE OPERATION |
|
PV INPUT (DC) |
|
Nominal DC Voltage/Max. DC Voltage |
720 VDC/900 VDC |
Start-up Voltage/lnitial Feeding Voltage |
320 VDC/350 VDC |
MPP Voltage Range |
400 VDC-800 VDC |
Number of MPP Trackers |
2/2x18.6A |
Maximum Input Current |
2/2x18.6A |
GRID OUTPUT (AC) |
|
Nominal Output Voltage |
230 VAC (P-N)/400 VAC (P-P) |
Output Voltage Range |
184-265 VAC* per phase |
Nominal Output Current |
14.5A per phase |
Power Factor |
> 0.99 |
EFFICIENCY |
|
Maximum Conversion Efficiency (DC/AC) |
96% |
European Efficiency@Vnominal |
95% |
OFF GRID OPERATION |
|
AC INPUT |
|
AC start-up Voltage |
120-140 VAC per phase/180 VAC per phase |
Auto Restart Voltage |
170-280 VAC per phase |
Acceptable Input Voltage Range |
170-280 VAC |
Max. AC Input Current |
40A |
PV INPUT (DC) |
|
Max. DC Voltage |
900 VDC |
MPP Voltage Range |
400 VDC-800 VDC |
Number of MPPTrackers/Max. Input Current |
2/2x18.6A |
BATTERY Mode Output (AC) |
|
Nominal Output Voltage |
230 VAC (P-N)/400 VAC (P-P) |
Output Waveform |
Pure Sine Wave |
Efficiency (DC to AC) |
91% |
HYBRID OPER/EON |
|
PV INPUT (DC) |
|
Nominal DC Voltage/Max. DC Voltage |
720 VDC/ 900 VDC |
Start-up Voltage/lnitial Feeding Voltage |
320 VDC/ 350 VDC |
MPP Voltage Range |
400 VDC-800 VDC |
Number of MPP Trackers/Max. Input Current |
2/2x18.6A |
GRID OUTOUT (AC) |
|
Nominal Output Voltage |
230 VAC (P-N)Z 400 VAC (P-P) |
Output Voltage Range |
184-264.5 VAC* per phase |
Nominal Output Current |
14.5A per phase |
AC INPUT |
|
AC Start-up Voltage/Auto Restart Voltage |
120-140 VAC per phase/180 VAC per phase |
Acceptable Input Voltage Range |
170-280 VAC per phase |
Max. AC Input Current |
40A |
BATTERY MODE OUTPUT (AC) |
|
Nominal Output Voltage |
230 VAC (P-N)/400 VAC(P-P) |
Efficiency (DC to AC) |
91% |
BATTERY& CHARGER |
|
Battery DC Voltage |
48V |
Max. Charging Current |
Default 60A, 10A-200A (Adjustable) |
GENERAL |
|
PHYSICAL |
|
Dimension, DxWxH (mm) |
167.5x500x622 |
Net weight (kgs) |
45 |
INTERFACE |
|
Communication Port |
RS-232/USB and CAN Interface |
ENVIRONMENT |
|
Humidity |
0 -90%RH |
Operating Temperature |
-10 to 55 ℃ |
Altitude |
0-1000 m** |